WELCEOM TO TAI'AN CITY RUIHENG BUILDING MATERIALS CO., LTD OFFICIAL WEBSITE
Language: 中文版 ∷  英文版

Company new

Construction Guidelines for Geocell Retaining Walls: From Preparation to Quality Assurance

  1. Construction Preparation

  • Material Preparation: Geocells must meet design specifications for strength, durability, and UV resistance. Prepare well-graded fill materials (sand, gravel, soil) free of impurities.

  • Survey Marking: Use surveying instruments to precisely mark the retaining wall's axis and boundaries per design drawings, with clear reference indicators.

  • Site Leveling: Clear debris and compact the subgrade to achieve required bearing capacity (≥95% compaction for cohesive soils).

  1. Foundation Construction

  • Trench Excavation: Mechanically or manually excavate to design depth/width, maintaining stable side slopes (typically 1:1 for temporary excavations).

  • Base Preparation: For weak subgrades, apply stabilization methods (e.g., 150mm gravel replacement layer compacted to 98% Proctor density).

  • Concrete Footing: Install reinforced concrete footing (e.g., C25 grade) with proper vibration curing (7-day minimum before geocell installation).

  1. Geocell Installation

  • Deployment: Unroll geocells along the foundation without twisting (allow 5% slack for thermal expansion).

  • Anchoring: Secure edges with U-pins (30-50cm spacing; 20cm at corners). For multi-layer systems, interlock layers with polymer connectors.

  • Seaming: Connect adjacent geocells via welding (120°C hot wedge), tying (UV-resistant straps), or patented clip systems.

  1. Fill Placement

  • Material Selection: Permeable fills (e.g., GW-GM soils with ≤25mm particle size) preferred to prevent hydrostatic pressure.

  • Layered Compaction: Place 200-300mm lifts, compacting with vibratory rollers (4-6 passes at 2km/h) to achieve ≥92% relative density.

  • Quality Control: Conduct nuclear density tests after each lift; avoid geocell distortion during compaction.

  1. Facade Installation (If Applicable)

  • Panel Selection: Precast concrete (50MPa) or HDPE panels (8mm thickness) with interlocking designs.

  • Mounting: Attach using galvanized brackets (M12 bolts) or polymer mortar, maintaining ≤3mm/m surface evenness.

  1. Drainage System

  • French Drains: Install 300mm×300mm gravel-filled trenches behind walls (2% slope) with geotextile-wrapped perforated pipes (100mm Ø).

  • Weep Holes: Space PVC pipes (50mm Ø) at 2m intervals vertically/horizontally, protected by non-woven geotextile filters.

  1. Capping & Landscaping

  • Structural Cap: 150mm-thick reinforced concrete coping or anchored geotextile (500g/m²) for erosion control.

  • Vegetation: Plant deep-rooted species (e.g., Vetiver grass) with growth medium (300mm topsoil layer).

  1. QA/QC Protocols

  • Material Testing: Verify geocell tensile strength (≥25kN/m per ASTM D4595) and fill compaction (Proctor standards).

  • Dimensional Tolerance: Wall verticality ≤1:200; surface evenness ≤10mm/3m straightedge.

  • Final Inspection: Review as-built drawings and conduct load tests (proof rolling at 80% design load).

Key Innovations:

  • Smart Anchoring: GPS-tracked U-pin placement ensures uniform stress distribution.

  • Eco-Engineering: Integrated vegetation enhances structural stability through bio-reinforcement.

Pro Tip: For seismic zones (≥0.3g PGA), incorporate biaxial geogrid reinforcement between geocell layers and increase weep hole density by 30%.

Maintenance Alert: Annual inspections should check for:

  1. Geocell exposure (>5% surface area requires immediate coverage)

  2. Weep hole clogging (flush with pressurized water if flow <1L/min)

  3. Facade joint separation (>6mm cracks need epoxy injection)


CONTACT US

COMPANY:TAI'AN CITY RUIHENG BUILDING MATERIALS CO., LTD

Contact:Nickle Nie

Tel:008615866038408

Phone:008615866038408

Email:nickle@rhgeos.com

Add:NO.3566 LONGQUAN ROAD,TAI'AN HI-TECH ZONE,SHANDONG PROVINCE,CHINA